/ Electronic controls


                                   HYGIENE AND INFECTION CONTROL

                                   Opens/closes automatically                 Energy savings
                                   with no manual contact                     Electronic mixers and taps do not require much
                                   DELABIE’s electronic mixers and taps are operated    energy to operate. On the battery-operated
                                   by active infrared detection.              models, DELABIE has chosen infrared active pulse
                                   Flow opens when the detector senses hands    technology, a low-power consumption solution.
                                   and shuts off automatically when hands are removed   The infrared beam is emitted intermittently saving
                                   from the detection zone.                   energy while ensuring effective detection.
              Hygiene and infection control  No manual contact prevents the spread of germs by   Battery-operated models have an average lifespan
                                   hand.                                      of 350,000 cycles (i.e. 3 to 6 years) depending
                                                                              on the frequency of use. The Lithium batteries
                                   Anti-bacterial duty flush programme        are widely available, affordable and recyclable.
                                   If a mixer or tap is not used for prolonged periods,   The significant hot water savings provided by
                                   water stagnates in the pipework, favouring the   DELABIE’s mixers and taps also result in energy savings.
                                   development of bacteria (isolated points-of-use,
                                   facilities closed during holidays, etc.).   Environmental labels
                                   DELABIE’s electronic mixers and taps have a duty   The water and energy saving performance
                                   flush programme.                            of DELABIE’s electronic controls means that the
                                   An automatic flush takes places for approximately   buildings achieve the highest performance standards
                                   60 seconds every 24 hours after the last use (can be   for international rating schemes such as BREEAM,
              Reduced-stagnation   programmed on some models).                LEED or HQE.
              solenoid valve
                                   Reduced-stagnation solenoid valve
                                   Most solenoid valves are fitted with a rubber membrane   SPECIFICALLY DESIGNED
                                   behind which water stagnates and is not renewed.
                                   This can lead to bacterial proliferation.  Easy to install
                                   DELABIE has developed a technology without a   DELABIE’s products are easy to install and
                                   membrane (patented system).                adjustments are kept to a minimum in order to save
                                   With this piston-operated solenoid valve, water    time during installation.
                                   is drained and renewed with every use which reduces
                                   bacterial development.                     • Independent electronic control unit:
                                   The solenoid valves’ self-cleaning system with      BINOPTIC, TEMPOMATIC 2 and TEMPOMATIC
                                   a calibrated groove reduces the build-up of dirt.  PRO models:
              No manual contact                                                Depending on the model, there is an option to adjust
                                   Furthermore, its slow closure eliminates water-hammer.
                                                                               the presence detection distance, to change
                Conventional   DELABIE                                         the operating mode (ON/OFF or automatic)
                 mixer    mixer
                 9 lpm    3 lpm    90% WATER AND ENERGY                        and change the duty flush settings.
                 0%      90%                                                   The electronic control units are waterproof (IP65)
                                   SAVINGS                                     with diagnostic LEDs to facilitate servicing.
                                                                              • Electronic unit and solenoid valve integrated
                                   Water savings                               in the body of the mixer/tap*:
                                   Compared to conventional mixers and taps,     TEMPOMATIC 4 and 5 models:
                                   DELABIE’s electronic mixers and taps can offer   Can be installed on any isolated point-of-use,
                                   maximum water savings. They ensure the manager’s   for new builds as well as renovation.
                                   water bills can be reduced whilst preserving user   - 6V Lithium batteries*:
                                   comfort.                                    There are no electrical connections required.
                                   • Automatic shut-off and split delivery     Simply connect the flexibles to the supply pipes
                 4.8L     0.6L      The mixer or tap shuts off automatically when   in the same way as for a conventional mixer/tap.
                                    hands are removed from the detection zone.    No special adjustment is necessary; the mixer/tap
                 32 sec.  12 sec.   This removes the risk of waste through negligence.    is ready to operate independently for 3 to 6 years.
                                    The anti-blocking security system activates   A red LED will flash for 15 days to indicate that
              Water saving per use  to prevent the mixer or tap from flowing continuously.   the battery life is low. The battery can be changed
                                    The flow time is reduced to the necessary minimum   without shutting off the water supply or removing
                                    (wetting, rinsing).                        the mixer/tap.
                                                                               The batteries are directly accessed through the
                                   • Flow rate regulated at 3 lpm              head of the tap (TEMPOMATIC 4) or via a battery
                             YEAR   DELABIE’s electronic mixers and taps are regulated   - 230/6V mains (plug-in or recessed)* :
                                                                               pack attached to the flexibles (TEMPOMATIC 5).
                                    at 3 lpm. The flow rate remains constant regardless
                                    of pressure variations in the system. The flow rate
                                    can be adjusted from 1.4 - 6 lpm.          To operate, simply connect the flexibles to the supply
                  WARRANTY                                                     pipes and connect the electrical supply to the mixer/
                                                                               tap via a plug and socket or recessed connection
                                                                               close to the basin. This does not require any specific
                                                                               maintenance (no battery changes).
                                                                              * Depending on the model.

                                                                              30-year warranty against any manufacturing defects.
                                                                              50 years repairability.