Page 143 - Water_Controls_for_Public-Commercial
P. 143

Point-of-use filters /


                     •  BIOSAFE: immediate protection against waterborne nosocomial infections (Legionella spp., Pseudomonas Aeruginosa, etc.)
                     •  Quick and easy to install: connect without tools or shutting off the water supply, filters suitable for all types of water controls
                     •  Filtration area: larger than flat membranes
                     •  Space-saving: suitable for taps with low drop heights

            BIOFIL shower filter                BIOFIL tap or wall shower filter
            Anti-Legionella and all-germ       Anti-Legionella and all-germ
                                                                                   Additional fittings







                                                                                                                          SHOWERS


                                                                                   Push-fit connector
                                                                                   • Simple to connect to the point-of-use
                                                                                    requiring treatment, no tools required.
                                                                                   • Standard or vandal-resistant versions
                                                                                    available.


            • Single use shower filter with     • Single use tap or wall shower filter with
             0.1µm nominal sterilising grade.    0.1µm nominal sterilising grade.               Vandal-resistant version:
            • Quick to install: screws on to all standard   • Hydrophilic polyethylene hollow fibres.   Tamperproof connector
                                                                                                prevents vandalism and
             shower hoses.                     • Maximum lifespan: 2, 3 or 4 months.            unauthorised removal of filter.
            • Hydrophilic polyethylene hollow fibres.  • Space-saving, suitable for taps with low drop
            • Maximum lifespan: 2, 3 or 4 months.  heights.
            • Filtration flow rate: 11.2 - 11.8 lpm* at 3 bar   • Filtration flow rate: 5.5 lpm* at 3 bar
             depending on the model (filter only, excludes   for 2-month versions; 7.6 lpm* at 3 bar
                                                                                      24x100      24x100      22x100
             any flow rate restrictor/regulator in the shower).   for 3 and 4-month versions (filter only,
            • Compatible with and resistant to chemical and   excludes any flow rate restrictor).   25  25  23
             thermal shocks.                   • Careful management of retro-contamination:            Ø 3
            • Non-sterile and sterile filters, individually   protective skirt and filter position is optimised   Ø 26  Ø 31  Ø 26
             wrapped.                            thanks to a tilted connector.
                                                                                     820124N     821124     820122N
            • Non-sterile filters:              • Compatible with and resistant to chemical
             CE marked class I Medical Devices.  and thermal shocks.                   22x100      1/2"       1/2"
            • Sterile filters:                  • Non-sterile and sterile filters, individually
             CE marked class Is Medical Devices.  wrapped.                          24          25         26
            • Very light hand spray:           • Non-sterile filters:                       Ø 3                    Ø 3
             - 2-month version:                  CE marked class I Medical Devices.    Ø 31       Ø 26        Ø 31
                empty filter: 105g; filter filled with water: 186g.   • Sterile filters:    821122   820123     821123
             - 3 and 4-month versions:           CE marked class Is Medical Devices.
                empty filter: 133g; filled with water 253g.                                                    24x125
                                                                                                  24x125
                                               *Average flow rate during the product lifespan.  16,5x100
            *Average flow rate during the product lifespan.                                                 28
                                                                                    21          25
                                                                                                                  Ø 3
                                                         shower spray    laminar flow  Ø 26       Ø 26        Ø 31
                                                                                     820126N     820125     821125
                                                                        Ø 11
                                                             Ø11
                                                 Ø 11
                 194                 194
                        62                  77         44  60      50  66     63  79
            1/2"                                                                   Push-fit connector for tap filter
                     Ø 56      1/2"
                                        Ø 56     Ø 56        Ø 56       Ø 56       M24/100                  820124N
                 30261              30361       30250/30251  30350/30351  30450/30451  M24/100, vandal-resistant  821124
                                                                                   F22/100                  820122N
                                                Tap / wall shower filter  Sterile  Non-sterile  F22/100, vandal-resistant  821122
                                                2-month, shower spray  20250  30250  M½"                     820123
                                                2-month, laminar flow  20251  30251  M½", vandal-resistant    821123
            Shower filter        Sterile  Non-sterile  3-month, shower spray  20350  30350  M16.5 100        820126N
            2-month lifespan    20261  30261    3-month, laminar flow  20351  30351  Push-fit connector for wall shower filters
            3-month lifespan    20361  30361    4-month, shower spray  20450  30450  M24X125                 820125
            4-month lifespan    20461  30461    4-month, laminar flow  20451  30451  M24 125, vandal-resistant version  821125
            *Reference applies to a single unit. Can only be   *Reference applies to a single unit. Can only be   These connectors are suitable for use with the new
            ordered in multiples of 10 (packaged in boxes of 10).   ordered in multiples of 10 (packaged in boxes of 10).   range of filters shown opposite.

                                                                                                        Showers  141
   138   139   140   141   142   143   144   145   146   147   148