Page 175 - Water_Controls_for_Public-Commercial
P. 175

Time flow urinal valves /


            60% WATER                                 TECHNICAL SOLUTIONS SUITABLE
            AND ENERGY SAVINGS                        FOR ALL CONSTRAINTS

            A smaller rinsing area                    Public and commercial buildings have different
            Due to the smaller bowl size, a standard urinal uses up   requirements depending on the place of installation
            to 6 times less water than a WC pan.      and type of user.
                                                      DELABIE has developed specific products to respond
            Optimised time flow                        to a variety of challenges (comfort, design,
            DELABIE’s urinal valves are more economical in terms   new buildings, refurbishment, users with specific
            of water than most of the valves available on the market.    needs, etc.).           Optimised time flow
            Time flow is set at 3 seconds instead of the usual
            7 seconds, resulting in up to 60% water consumption   Soft technology: soft-touch operation  Conventional   DELABIE
            savings whilst maintaining appropriate hygiene levels.  DELABIE has developed time flow controls    valve   valve
                                                      with a soft-touch operation.                   0%      60%
            Efficiency                                 Soft technology allows all users (children, the elderly
            With a minimum flow rate of 0.15 L/sec. for 3 seconds,   or people with reduced mobility) to use the controls
            the water volume is 45cl which is enough to renew   with no effort required.
            the water in a conventional trap. This flow rate can be   TEMPOSOFT 2 and TEMPOFLUX models are fitted
            adjusted during installation.             with a priming system that requires half the effort
                                                      to operate, compared to conventional controls.
            Energy savings
            DELABIE's time flow urinal valves operate completely   Waterproof recessing
            autonomously with no need for an electrical supply.    TEMPOFLUX features DELABIE's newest generation
            They do not consume any power at all.     of recessing housings. This housing is 100%
                                                      waterproof and can be installed on different fixtures   1.05L  0.45L
            Ecological                                (rails, solid walls, panels) and can be adapted to fit
            DELABIE's time flow urinal valves are made from    different wall thicknesses from 10 - 120mm.  7 sec.  3 sec.
            materials that are 100% recyclable which ensures
            that the products receive the best ecological   Types of installation                Water savings per use
            assessment in their category.             For refurbishment projects in particular, the water
                                                      supply, available pressure or the associated urinals
            Environmental labels                      can be a problem for the installer.
            The water and energy saving performance    DELABIE offers urinal valves with in-line or angled
            of DELABIE’s time flow urinal valves means that    inlet supply, with ½" union (with ~3 or 7 seconds time
            the buildings achieve the highest performance   flow).
            standards for international rating schemes such
            as LEED, BREEAM or HQE.                                                                                       URINALS
            For more information see page 8.

                                                                                                 Soft technology:
                                                                                                 soft-touch operation
            SPECIFICALLY DESIGNED FOR
            COMMERCIAL ENVIRONMENTS

            Superior endurance
            The time flow mechanisms in DELABIE's urinal valves
            are hard-wearing.
            The hydraulic timing system with a calibrated groove
            is self-cleaning, which extends its lifespan to over
            500,000 operations.
            There is no metal-metal or metal-plastic friction,
            ensuring reliable and durable timing.                                                Vandal-resistant
            DELABIE's water controls perform to the highest
            standards. Each model is subjected to endurance
            tests under extreme conditions in endurance
            laboratories.








                                                                                                 Endurance









                                                                                                          Urinals  173