Page 37 - Water_Controls_for_Public-Commercial
P. 37

Electronic basin controls BINOPTIC 2 /





            DOWNLOAD OPERATION HISTORY                           MEMORY AND COPY SETTINGS FEATURE

                                With the DELABIE Connect app, it is also              The " copy-paste " feature allows
                                possible to get usage statistics for                  selected settings to be saved in the app
                                the tap: like total uses, total number of             and copied to other taps.
                                duty flushes carried out and their length,             A sure way to save time when installing.
                                or even the total number of thermal                                                       BASINS
                                shocks carried out.
                                This report can be sent by email.








            TECHNICAL SUPPORT
                                If required, diagnostics can be managed
                                remotely by DELABIE Technical Support.
                                A report of usage and settings
                                can be sent by email.










                                                                 Wall-mounted BINOPTIC MIX 2 Bluetooth  electronic mixer ref. 484010E
                                                                                         ®




              No Smartphone, no problem!

              Using a smartphone and the DELABIE app isn't essential for making the main adjustments.
              These settings can also be made directly on taps. Just insert a 1.5mm Allen key in the small hole designed for adjustments and change
              the settings by pressing the button.


                                  Thermal shock (red LED)                            Duty flush (green LED)
                                  The tap begins a 10, 20 or 30 minute               The duty flush is set to activate 24
                                  flush to carry out a thermal shock. This            hours after the tap was last used. It can
                                  flush can be stopped by the user                    be modified to 12 hours or turned off.
                                  by pressing the button or by passing a
                                  hand in front of the sensor, to prevent
                                  any risk of scalding.



                                  Detection range (white LED)
                                  The infrared sensor range can be
                                  adjusted to suit all configurations.
















                                                                                                          Basins  35